All
goods will be subject to availability.
-
Once
delivered goods cannot be exchanged or returned.
-
Delivery
dates are given in good faith as supplied by the manufacturers
or their distributors. We will not be liable for any failure
to effect delivery of the whole or part of any order due to
any events, errors or any other circumstances. If delivery is
delayed we will notify you as soon as we are aware of the delay
and you agree to give us such an extension to effect delivery
as is reasonable in the circumstances, especially when goods
are customized to your requirements. For non-customized goods
you can cancel the order without penalty on both sides.
-
Please
do not book installations of equipment before delivery to give
you chance to receive the equipment. We will not be held responsible
for any additional expenses you may incur, for instance, late
installations.
-
Please
allow ample time for equipment to be delivered which is required
for time critical missions, such as exhibitions, presentations,
etc., as we will not be held responsible for any additional
expenses your may incur.
-
Goods
MUST be checked for physical damage before signing to accept
delivery from the courier. If the goods are damaged or broken,
please DO NOT sign for the goods. Contact Bela Interactive Installations
Ltd immediately by telephone 01268 764800 or 07834 480770. When
signing for acceptance of your goods, you are signing to accept
ownership of your goods in perfect physical condition. If you
do not check the goods at time of signing, and the goods have
been broken in transit, you will forfeit your right to reject
the goods for physical damage and we cannot replace or take
back your goods.
-
Once
you have accepted your goods, please note you have 2 working
days to check that your product is working satisfactory exceptions
are interactive whiteboards and acosiated products.Should the
goods not work satisfactorily you must contact us to obtain
a returns number in order that arrangements can be made for
collection and inspection, providing the goods are undamaged,
unused, and in their original packing and you have not marked
either the goods or their packing in any way. If you fail to
comply with these terms you will be deemed to have accepted
the goods.
-
Please
note you will be responsible for all shipping and insurance
charges for returns, unless otherwise indicated. If you choose
not to insure your package, and we do not accept return of the
Product for reasons stated above, you will be responsible for
any loss or damage. The purchase price (less any applicable
open box fees or missing parts fees) will be credited upon our
acceptance of the merchandise in as-new condition in conformity
with this policy.
Please
allow 5-10 business days to process any refunds. Additional
charges may be assessed for Products returned with any missing
parts and/or accessories.
-
Goods
returned in undamaged, unused condition and in their original
packing which has not been defaced in any way, will be inspected
by the manufacturer or their distributor and a replacement or
return of your goods will be made based on their decision.
-
After
two working days, the manufacturers warranty comes into effect.
Please note goods are NOT sold on a sale or return basis.
-
Bela
Interactive Installations Ltd will not be responsible for any
labour charges, rental charges, loss of profits, charges, expenses,
any other charges nor consequential loss or damage as a result
of delivery delays, incorrect goods or defective goods being
delivered to its customers.
11.
Installations:
Customer
Obligations – Terms and Conditions
1.
Inform Bela Interactive as soon as possible if you need to
cancel
or change the installation date. For cancelling or postponing
an installation with less than 5 working days notice a charge
of £250 for each confirmed system install will be imposed
unless another job can be allocated.
2. Ensure on site parking or allocated space near to the installation
works as possible any car parking fees to be paid for by the
customer if wheel clamping is in force any unauthorised clamping
fees to be paid for by the customer.
3. Ensure that the room or rooms are vacated, clear from wall
obstructions (where the IWB will be fitted and available for
installation on the dates agreed.
4. Ensure that a site representative is available to sign for
the equipment and the work completed on the installation date.
5. Arrange for the room and representative to be available for
a site survey prior to installation.
6. Inform Bela Interactive of any potential health and safety
risks in the building construction.
NB: VERY IMPORTANT HEALTH AND SAFETY INFORMATION FOLLOWS:
In the best interests of our customers and Bela Interactive
staff, our engineers are trained to carry out their work in a
safe and proper manner. They are instructed to keep in mind the
safety of the building occupants as well as themselves. To assist
us we ask you to inform us of any known hazards our engineers
may encounter on your premises
In particular we need to be aware of any asbestos in the vicinity
of the proposed installation. (Asbestos is likely to be present
in the building if it was built or refurbished between 1950 and
1980.)
· If you are unsure whether there is asbestos on site, we must
ask you to find out before we start work.
· If you have an Asbestos Register, we request that it be checked.
If the area is clear we require a written statement to that effect,
including a copy of the relevant section of the Register.
· If there is asbestos in the area where we are to work, we need
a copy of the Register in order to plan a safe method of work.
· Our engineers are instructed not to disturb asbestos. During
an installation, if our engineers uncover any hidden material
or dust that they suspect may contain asbestos, they will stop
work and will inform the premises site manager.
We would be grateful for your co-operation in order to minimise
any health risks or delay during the installation.
5.A
Two double 240V 13A a.c. sockets will be required at the PC location
to power the IWB board and ancillaries.
7. Provide a stable structure. If the ceiling suffers from vibration
or disturbance from movement either within or from above, this
will cause the projected image to move. Bela Interactive will
not be held responsible for this. Bela Interactive may decline
to ceiling mount the projector if a suitable structural support
is not available (if site is not site surveyed in the first instance)
8. Provide a 240V 13-amp a.c. Electrical mains socket at the
ceiling mounting point for the projector unless otherwise agreed.
The socket should be located on the ceiling perpendicular to
the proposed centre of the Interactive White Board as close to
the projector mounting point as possible. The exact location
of the socket will depend on chosen projector model. This socket
could be fitted after the installation. Bela Interactive personnel
are not authorised to carry out mains electrical installation
work.
9. For Active Speakers a 240V 13-amp a.c. single electrical
mains socket at a location within .5 metres of the Interactive
Board.
10.
Provide a CD rom capable pc or laptop with a supported operating
system
such as Windows 2000/XP/Vista installed, in time for the
installation if there is no pc or laptop at the time of installation
we will test with the engineer’s laptop for proper functions
of the installed system including video and sound.
11. You the Customer to dispose of whiteboard and projector packaging.
We will how ever leave the rooms in the state that we find them
with packaging neatly packed ready for disposal.
12. Non-Standard Installations. If you cannot meet any of these
requirements or wish to have the equipment installed in a different
manner to that described above, you must inform us as soon as
possible before the agreed installation date. Bela Interactive
will endeavour to accommodate any reasonable request and liaise
with architects or builders on any installation, but this may
incur additional cost.
These conditions explain what a Standard Installation consists
of. For a Non-Standard Installation this document does not apply
please phone us for more information. The conditions also set
out what requirements must be fulfilled by you, the customer,
so that a successful installation can be carried out.
There are five main processes that are carried out when installing
a standard Interactive Board system. These are:
I. Installing the Interactive Board;
II. Installing the Data/Video Projector;
III. Installing the Cabling and data termination boxes;
IV. Installing the Software;
V. Testing and Commissioning the Installation.
VI. Sign off customer satisfaction sheet.
I. Installing the Interactive Board.
· Bela Interactive will wall mount the base of the board at either
the
Standard height of 90mm from the floor (78” diagonal unit
Promethean) (80” Smartboard) or 1135mm from the floor (64” diagonal
unit Promethean) (60”Smartboard)
If you would like the board to be higher or lower please inform
the installation team before the whiteboard is fitted.
· The
board will be fixed to the wall via four mounting brackets.
· If wall mounting is not possible then the board will require
mounting on a mobile stand at extra cost for the stand available
from our website.
Activ+2
Version 2 Systems: Smart680i ESP systems: Bela
Interactive Promethean ESP: Site Survey required for this type of installation
please phone 01268764800 to arrange.
Solid wall construction or studded wall construction at best
required for this type of system. We may need to brace/span the
wall for the fixing points also please keep in mind any obstructions,
as we may have to use step out brackets for the frame at extra
cost to you the customer currently £60.00 per set. Termination
is either side of the frame unless you require this to be elsewhere
i.e. back of the room this will incur a extra cost of £110.00
per system. At least one double electrical socket required at
the point of install. Only accredited Promethean engineers of
whom Bela Interactive Ltd is a certified member can install active+2
Version 2 systems and ESP systems.
Plasma/Lcd screen installation:
Solid
wall construction or studded wall construction at best required
for this system. Wall mounted electrical single socket
required. Electrical sockets can be installed at extra cost to
you the customer currently £150 each per spurred double
point. Cables all terminated either side of the installation
if you require termination else where this is charged extra subject
to site survey
II. Installing the ceiling mounted data/video projector.
· Bela Interactive will ceiling mount the base of the projector
at a height preferably no lower than 2.1 metres from the floor
unless room conditions dictate otherwise relative to board height.
· The projector is usually positioned between 2.2m and 3.5m away
from the centre of the Interactive Board. (The distance is dependant
on the projector model and board size supplied). If you have
any concerns please contact Bela Interactive on 01268 764800.
· Safe projector installation is subject to suitable support being
available in the ceiling. The height and type of ceiling will
determine suitability (please refer to item 8 of customer obligations
page 1). If Bela Interactive considers the structure to be too
high or low and unsafe, we will not fix to it. Wall Mounted systems
available. Please note we do not install/ fix to a suspended
ceiling we need the structure above
· This practise is dangerous and unstable if we are asked to replace
a projector onto an existing pole mount system installed by another
company using this method we will refuse we will how ever install
to the main structure at extra cost to you the customer.
III. Installing and Connecting the Cabling.
· Bela Interactive shall install VGA and video cabling between
the ceiling mounted projector and surface mount outlet boxes.
· Bela Interactive shall install a Serial /USB data cable between
the wall mounted Interactive Board and the same outlet boxes
or active speakers.
· The outlet boxes shall be within a 3-metre cable run of the Interactive
Board and situated in the same room. This is usually next to
the board on either the left or right hand side.
· The outlet boxes shall have termination plates fitted providing
the following connections:
·
a) PC Audio. Two RCA sockets providing left and right audio channels.
b) Ancillary audio and video. Three RCA sockets providing video
and left and right audio channels
c) VGA single.
· Exiting the outlet boxes will be the following leads:
a) PC video lead (VGA plug for connection to video splitter)
Video splitters supplied at extra cost.
b) Data lead (serial or USB plug for connection to PC communications
port)
· A scart to phono lead shall be provided to enable scart connection
to ancillary equipment.
· A phono to 3.5mm stereo jack lead shall be provided to enable
audio connection to PC sound card
·
A video splitter can be provided at extra cost currently £35.00
to allow simultaneous operation of the projector and the PC’s
monitor. This comes with a 2m VGA lead for connection to the
PC graphics card.
· Bela Interactive will connect all the leads to the customer supplied
PC and ancillary equipment. If there is no suitable PC and no
ancillary equipment available at the time of install, the customer
must connect the leads themselves.
· The customers own PC and other ancillary equipment (e.g. VCR/
DVD player) should be positioned within 2 metres of the outlet
box, on a desk or other customer supplied furniture.
· All cabling shall be enclosed in plastic surface 25x16 white
trunking and, if available, the room ceiling void.
IV. Installing the Drivers/Software.
·
Bela Interactive will install the Interactive Board driver/software
on a customer supplied PC or Laptop with full admin rights required
Bela Interactive cannot accept responsibility for configuration
and/or installation of any other aspect of customer’s PC.
·
If there is no PC provided on the day of the installation, then
the customers must install the Drivers/Software themselves. If
you require a later visit there will be a charge for this. Currently £75
call out unless agreed otherwise.
V. Testing and Commissioning the Installation.
· Bela Interactive engineers shall test and commission the completed
installation.
·
Testing shall be carried out by reference to the checklist on
the ‘Installation Sign-off Form.’
· Any problems that cannot be resolved shall be noted on the sign-off
form.
· Notes on the sign-off form will include any further action required
as agreed between the customer and the installation engineer.
· Once completed the engineer and the customer must both sign the
sign-off form.
ACCEPTANCE OF INSTALLATION CONDITIONS.
Installation Date agreed with Bela Interactive Installations
Ltd: _______________________
I have read and accepted the Bela Interactive conditions of
installation
Print Name _____________________________ Organization _________________________________
Signature _____________________________ Date ________________________
FOR PRE-INSTALLATION QUERIES CALL BELA INTERACTIVE INSTALLATIONS
LTD ON 01268764800
PLEASE POST BACK TO
Bela Interactive Installations Ltd
44, Kingsley Meadows,
Wickford,
Essex,
SS12 9FN.
Alternately Fax Back to 01268 561623